GSK988TD Drive X Axis Not Enable Hold+ ,Hold-

  GSK988TD Package User:

Drive X Axis Not Enable Hold+ ,Hold-

  How to Set Parameter Servo or Controller Config to Servo Axis

 

 

CNCmakers Support:

 

Regarding Drive X axis not enable Hold+ Hold-

 

  1. Please kindly check the Brake control relay indication light is on or not? (the coil has 24V or not), if the relay indication light is on, then it could be poor contact for the touch point, you can change the relay base and check again.
  2. If the relay indication light is not on, then it could be CN7 port of the driver broken, please connect the Hold+ and Hold- to another driver, and see if the indication light of brake control relay is on or not.

 