GSK983MA 410 and 413 alarm

 GSK983Ma and DA98B-20 User:

Dear Sir,
Again we have another burned drive on another machine.
So we replaced the drive by a new one.
1.    Which parameters should we change in the new drive?
2.    What does errors 410 and 413 mean?
 
CNCmakers Support: 
You can copy the parameters from original driver.
 
GSK983Ma and DA98B-20 User:
The original drive is damaged, and does not turn on anymore, so we cannot see its parameters.
Do you know which parameters should we change, in the new drive?
 
CNCmakers support:
DA98B-20 driver parameter
If PA22 = 1, please change it to 0.
If PA22 = 0, then please change it to 1.
 
 
GSK983Ma and DA98B-20 User:
Dear King,
Kindly, we changed the parameter, and the X axis is now running, but in the opposite direction.
Which parameters should we change, to have the servomotor run in the other direction?
 
CNCmakers Support:
If so, please press the emergency button.
then change both PA19 and PA22 to opposite value, change both at the same time, not one by one.
(if it is 0, change to 1, if it is 1 then change to 0)
After both PA19 and PA22 change to opposite value, then save the parameters.
And then restart the power on.