FANUC external operation information history

What are the functions of FANUC operation history:
1>Able to find some recent key history
2>Able to view some parameter modification records
3>Able to view tool compensation change records
4>Can query alarm records
5> It is also possible to customize some signal addresses and record the changes of these signals in the operation history;
 
How to set the number of FANUC external operation information history? ?
The editor has compiled some settings related to the operation history for everyone
 
 
3111#7=1 When an alarm occurs, it will not automatically jump to the alarm information screen
 
3116#2 PWR alarm SW0100, "parameter writing switch is on"
0: Clear by "CAN" + "RESET" operation.
1: Clear by "RESET" operation or external reset ON.
 
3112#2 Whether OMH displays the external operation information history screen
0: Do not display. 1: To be displayed.
 
 
3112#3 Does EAH register external alarm/macro alarm information in the operation history/alarm history function?
0: Do not log in. 1: Log in.
 
 
1>Modify NC parameter 3106#4=1
 
2>Turn the right page several times, you can see the operation history